DISCUSSION

EFT and Shibboleth IDP time servers can differ by 3 minutes. SAMLSSOClockSkewToleranceInMs is used to adjust the clock skew. You can adjust the setting for a more lenient clock skew (higher than 3 minutes). For example, if the EFT Server's SAMLSSOClockSkewToleranceInMs value is set it to 180000 (3 minutes), a clock difference between EFT and the IDP time server of 30 minutes results in a rejected assertion. The EFT server service must be restarted to take effect.

32-bit:

HKEY_LOCAL_MACHINE\Software\Software\Globalscape Inc.\EFT Server 7.3\

64-bit:

HKEY_LOCAL_MACHINE\Software\WOW6432Node\GlobalSCAPE Inc.\EFT Server 7.3\

Type: DWORD

Value name: SAMLSSOClockSkewToleranceInMs

Default Value: 180000

Minimum Value: 0

Maximum Value: 4294967295

Cached: yes

Backup/Restore: Yes

Restart required: Yes