THE INFORMATION IN THIS ARTICLE APPLIES TO:
DISCUSSION
EFT and Shibboleth IDP time servers can differ by 3 minutes. SAMLSSOClockSkewToleranceInMs is used to adjust the clock skew. You can adjust the setting for a more lenient clock skew (higher than 3 minutes). For example, if the EFT Server's SAMLSSOClockSkewToleranceInMs value is set it to 180000 (3 minutes), a clock difference between EFT and the IDP time server of 30 minutes results in a rejected assertion. The EFT server service must be restarted to take effect.
32-bit:
HKEY_LOCAL_MACHINE\Software\Software\Globalscape Inc.\EFT Server 7.3\
64-bit:
HKEY_LOCAL_MACHINE\Software\WOW6432Node\GlobalSCAPE Inc.\EFT Server 7.3\
Type: DWORD
Value name: SAMLSSOClockSkewToleranceInMs
Default Value: 180000
Minimum Value: 0
Maximum Value: 4294967295
Cached: yes
Backup/Restore: Yes
Restart required: Yes